Direct answer

An IP code (IEC 60529) has two digits: the first rates dust protection (0–6), the second rates water protection (0–9K). For protective cases, IP67 means dust-tight plus 30 minutes of immersion in 1 metre of water; IP68 means dust-tight plus immersion deeper than 1 metre for a duration the manufacturer declares and verifies in testing.

## §01The two digits, decoded

The code is defined by the international standard IEC 60529. It is a tested condition, not a marketing tier — each number corresponds to a specific laboratory procedure.

| First digit | Dust protection | Test condition |
|---|---|---|
| IP5X | Dust-protected | limited ingress; equipment unaffected |
| IP6X | Dust-tight | no ingress in circulating talcum dust chamber |

| Second digit | Water protection | Test condition (IEC 60529) |
|---|---|---|
| IPX4 | Splashing water | splash from any direction, 10 min |
| IPX5 | Low-pressure jets | 6.3 mm nozzle, 12.5 L/min, ~3 m, ≥3 min/m² |
| IPX6 | Powerful jets | 12.5 mm nozzle, 100 L/min, ~3 m, ≥3 min/m² |
| IPX7 | Temporary immersion | 1 m depth, 30 minutes |
| IPX8 | Continuous immersion | beyond 1 m; depth/time declared by maker |

## §02What this means when buying a case

- **IP67 is the practical baseline** for a watertight protective case. It proves the gasket system survives full immersion — which is far more demanding than rain or hose spray.
- **IP68 is not automatically "better"** in a meaningful sense unless the declared depth and duration match your risk. A case rated IP68 at 1.5 m/30 min adds little over IP67 for most users; one tested to 5 m for an hour is a genuinely different design.
- **Ask for the declared test parameters.** A responsible manufacturer states the exact depth and duration behind an IP68 claim, because IEC 60529 leaves them to the maker.
- **Ratings apply to a closed, latched case** in as-shipped condition. A worn gasket, an unlatched corner or a damaged pressure valve voids the rating in practice.

**Note:** the IP code says nothing about impact protection, UV life or temperature range. A case can be IP67 yet brittle at −30 °C. Judge those attributes against separate standards (see our drop-test and temperature guides).

## §03Common buyer questions the rating does not answer

IP testing is performed on a new, correctly closed unit. Over a service life, three factors dominate real-world water ingress: gasket compression set, latch preload, and hinge/boss cracks that open a leak path. Specify replaceable gaskets and field-serviceable latches if the case will see thousands of open/close cycles.

## Frequently asked questions

### Is IP67 or IP68 better for a protective case?

IP68 is the higher rating, but only the declared depth and duration matter. A case tested to IP67 (1 m for 30 min) covers rain, spray, brief drops into water and deck conditions. Choose IP68 only when the declared immersion parameters exceed your real exposure.

### Can an IP67 case be submerged long-term?

No. IP67 certifies 30 minutes at 1 metre. Long-term or pressurised submersion requires an IP68 rating with declared parameters matching the duty, and even then gaskets age and must be inspected.

### Does IP67 mean dust can never get in?

For a new, correctly closed case, the 6 first digit means the dust test showed no ingress at all. In service, dust enters through the same paths water would: worn gaskets, unlatched corners or a stuck-open pressure valve.

### Is IP65 enough for outdoor use?

For rain, hose washdown and deck spray, IP65 is generally sufficient. Choose IP67/IP68 when the case can be dropped into water, submerged briefly, or used in heavy seas or flood-prone environments.

## Related guides

[KB-CERT-022Certification and Test Evidence: What to Demand From a Case Supplier](https://kexinn.org/certification-and-test-evidence-for-case-buyers/)[KB-MAT-002PP vs ABS vs Rotomolded PE vs Aluminum: Case Materials Compared](https://kexinn.org/case-materials-compared/)[KB-FOM-003Foam Inserts for Protective Cases: EPE vs EVA vs PU vs CNC-Cut](https://kexinn.org/foam-insert-guide/)